Libro Resumenes. VIII Jornadas de Investigación en Oftalmología 2026. Inteligencia artificial y transformación digital en investigación oftalmológica
VIII Jornadas de Investigación en Oftalmología · Universidad de Chile 67 rate the difficulty of the phacoemulsification step itself and, as far as possible, to disregard other factors influencing the overall difficulty of the procedure. This distinction is relevant because it brings the subjective outcome conceptually closer to CDE, which reflects ultrasound energy expenditure during phacoemulsification. Nevertheless, the two measurements capture different aspects of the same surgical step: CDE provides an objective measure of ultrasound energy use, whereas the surgeon-rated score reflects the perceived technical effort required to emulsify and remove the nucleus. The adjusted analysis further supported the relationship between the surgeon-rated score and CDE. After accounting for age and operating surgeon, each one-point increase in surgeon-rated phacoemulsification difficulty was associated with an estimated 35.5% increase in CDE. The association remained statistically significant after additional adjustment for either LOCS III-NO or BCN10, indicating that the subjective assessment retained an association with ultrasound energy expenditure after accounting for preoperative nuclear grade. These additional models were exploratory and should not be interpreted causally. Because the difficulty score was obtained after surgery, it is best regarded as a complementary contemporaneous measure of phacoemulsification complexity rather than as a preoperative predictor. This relationship was further supported by the categorical analysis. Median CDE increased from 4.99 in low-difficulty cases to 7.14 in intermediate-difficulty cases and 23.10 in high-difficulty cases. Both cataract grading systems showed similarly ordered increases across the three difficulty categories. Although categorizing a continuous score reduces statistical information and was therefore retained only as a secondary exploratory approach, the categories provide an intuitive clinical framework that may be useful for surgical case allocation and teaching. The multicenter and multisurgeon design adds real-world heterogeneity but also introduces potential sources of confounding. Ultrasound energy expenditure can be influenced by nuclear disassembly strategy, surgical technique, machine settings, and surgeon-specific behavior in addition to lens hardness. Previous comparative studies have demonstrated that nuclear fragmentation technique can modify ultrasound requirements, particularly in denser cataracts [7,8]. In the present cohort, however, 93.5% of included procedures used stop-and-chop. Restriction of the analysis to these 43 eyes produced nearly identical correlations and preserved the better model fit observed with BCN10, suggesting that the main findings were not explained by the small number of quick-chop procedures. The study has several strengths. Cataract grading was performed prospectively using two standardized systems. The operating surgeons were masked to both preoperative grades, reducing the risk that classification influenced surgical behavior or subjective scoring. Subjective phacoemulsification difficulty was recorded before disclosure of CDE, maintaining separation between the two outcome measures . The inclusion of six experienced cataract surgeons across two tertiary hospitals also increases the clinical heterogeneity and potential external applicability of the findings compared with a tightly standardized single-surgeon series. Several limitations should be acknowledged. First, this was a pilot study with a modest sample size and was not powered to demonstrate small differences between two highly correlated grading systems or to establish statistical equivalence. Second, all cataracts were graded by a single observer; therefore, interobserver reproducibility could not be assessed within the study cohort. Third, the surgeon-rated phacoemulsification difficulty scale was not formally validated. Although surgeons were explicitly instructed to assess the phacoemulsification step itself and to disregard other contributors to overall surgical difficulty, complete separation of these factors in subjective perception cannot be guaranteed. Fourth, the number of cases contributed by each surgeon was unbalanced and only six surgeons participated, limiting robust estimation of surgeon-level random effects. Surgeon was consequently modeled as a fixed effect in exploratory analyses. Fifth, surgical technique and phacoemulsification settings were not standardized, and procedure-specific machine parameters were not systematically recorded. Differences in ultrasound power, fluidics, aspiration settings, and other surgeon-specific parameters may therefore have contributed to variability in CDE independently of nuclear cataract severity. Alternative nuclear disassembly techniques were uncommon, precluding reliable estimation of an independent technique effect. Residual confounding by unmeasured phacoemulsification settings cannot therefore be excluded. Nevertheless, sensitivity analyses restricted to stop-and-chop procedures yielded consistent results. Sixth, CDE represents an objective measure of ultrasound energy expenditure but does not capture all technical components of phacoemulsification difficulty. Seventh, one participant contributed both eyes. Given that only one participant was bilaterally included, the potential impact of within-subject dependence on the overall estimates was likely limited; sensitivity analyses excluding either eye did not materially alter the principal correlations. Larger studies including a greater proportion of bilateral cases should explicitly account for patient-level clustering.
Made with FlippingBook
RkJQdWJsaXNoZXIy Mzc3MTg=