Libro Resumenes. VIII Jornadas de Investigación en Oftalmología 2026. Inteligencia artificial y transformación digital en investigación oftalmológica

VIII Jornadas de Investigación en Oftalmología · Universidad de Chile 66 Sensitivity analyses excluding either eye of the single bilaterally included participant did not materially alter the primary correlation estimates. Discussion In this prospective multicenter, multisurgeon pilot study, both LOCS III-NO and BCN10 demonstrated strong associations with CDE and surgeon-rated phacoemulsification difficulty. The two grading systems showed remarkably similar correlations with CDE, and both exhibited even stronger associations with the surgeon’s perception of the difficulty of the phacoemulsification step. In addition, surgeon-rated phacoemulsification difficulty correlated strongly with CDE and showed a clear stepwise increase in ultrasound energy across low-, intermediate-, and high-difficulty categories. The strong relationship observed between LOCS III-NO and CDE is consistent with previous evidence linking nuclear cataract severity to ultrasound energy requirements. Davison and Chylack reported exponential increases in phacoemulsification energy with increasing LOCS III nuclear opalescence and nuclear color in a large single-surgeon series, while cortical and posterior subcapsular opacity showed little relationship with intraoperative energy parameters [3]. Subsequent studies have similarly demonstrated associations between LOCS III nuclear grading and CDE or related phacodynamic measures [5]. Our findings extend this evidence to a prospective, multisurgeon setting involving two tertiary ophthalmic centers. BCN10 differs conceptually from LOCS III-NO by placing greater emphasis on nuclear hardness and extending its photographic reference spectrum to very advanced nuclear cataracts [4]. In the present study, BCN10 correlated strongly with both CDE and surgeon-rated phacoemulsification difficulty. However, its unadjusted performance was not statistically distinguishable from LOCS III-NO. The observed differences in Spearman coefficients were very small, and paired bootstrap CIs were compatible with either system having a slightly stronger relationship with the outcomes. Accordingly, the present findings should not be interpreted as demonstrating equivalence. Failure to detect a difference between two highly correlated grading systems is not equivalent to formal proof of equivalence or noninferiority. Rather, this pilot study provides no evidence of clear superiority of either grading system in unadjusted correlation analyses and provides preliminary effect estimates for appropriately powered confirmatory studies. From a practical standpoint, BCN10 may also offer advantages in routine clinical use. The system is presented as an A4-sized chart containing high-resolution photographic references across a broad spectrum of nuclear cataract severity, including cross-sectional and frontal slit-lamp images for each grade [4]. This format may facilitate direct comparison between the patient’s lens and the corresponding reference image during slit-lamp grading. In our experience, the system was straightforward to apply. However, grading time, interobserver reproducibility, ease of use, and examiner preference were not formally compared between BCN10 and LOCS III-NO in the present study. Therefore, any potential practical advantage of BCN10 remains hypothesis-generating and should be evaluated in dedicated comparative usability and reproducibility studies. Despite the nearly identical unadjusted correlations of LOCS III-NO and BCN10 with CDE, an exploratory difference emerged in multivariable model fit. The BCN10-based model had a higher adjusted R² and lower AIC and BIC values than the LOCS III-NO model after adjustment for age and operating surgeon. Because the two models used the same outcome, analytical sample, and covariate structure, these information criteria are directly comparable as measures of relative in-sample fit. This apparent discrepancy is not contradictory: Spearman correlation primarily reflects the strength of the monotonic ranking between nuclear grade and CDE, whereas regression model fit also reflects how well the numerical grading scale accounts for variation in log(CDE) after adjustment for other covariates. One possible explanation is that the broader grading range and nuclear hardness-oriented design of BCN10 may allow greater discrimination across increasing levels of nuclear severity. However, adjusted R², AIC, and BIC are descriptive model-comparison metrics and do not constitute a confirmatory test of superiority. Given the exploratory nature of these analyses and the limited sample size, the observed advantage in model fit should be regarded as hypothesis-generating and requires replication in an independent cohort. The high correlation between LOCS III-NO and BCN10 ( ρ =0.905) confirms substantial overlap in the nuclear characteristic captured by the two grading systems. This strong collinearity also argues against entering both variables simultaneously in a conventional multivariable model when attempting to estimate their independent effects. Separate adjusted models were therefore used in the present analysis. An important secondary finding was the strong correlation between surgeon-rated phacoemulsification difficulty and CDE. Unlike a global assessment of cataract surgery complexity, surgeons were specifically instructed to

RkJQdWJsaXNoZXIy Mzc3MTg=