Libro Resumenes. VIII Jornadas de Investigación en Oftalmología 2026. Inteligencia artificial y transformación digital en investigación oftalmológica

VIII Jornadas de Investigación en Oftalmología · Universidad de Chile 65 Outcome ρ LOCS III-NO ρ BCN10 ∆ρ * 95% CI for ∆ρ Difficulty score 0.842 0.862 − 0.020 − 0.119 to 0.075 * ∆ρ = ρ LOCS III-NO − ρ BCN10. Phacoemulsification Difficulty Categories CDE differed significantly among low-, intermediate-, and high-difficulty groups (Kruskal-Wallis H=20.81; P<0.001). Median CDE was 4.99 (IQR, 3.13–6.64) in low-difficulty cases, 7.14 (IQR, 6.56–11.17) in intermediate-difficulty cases, and 23.10 (IQR, 15.58–47.05) in high-difficulty cases. Holm-adjusted Dunn comparisons demonstrated significant differences between low and intermediate difficulty (adjusted P=0.017), low and high difficulty (adjusted P<0.001), and intermediate and high difficulty (adjusted P=0.015). LOCS III-NO also increased progressively across difficulty categories, with median values of 2, 4, and 6 in low-, intermediate-, and high-difficulty groups, respectively (H=29.44; P<0.001). All pairwise comparisons remained significant after multiplicity adjustment. Similarly, median BCN10 increased from 3 in low-difficulty cases to 5 in intermediate-difficulty cases and 8 in high-difficulty cases (H=31.94; P<0.001), with significant differences between all three groups. Table 4. CDE and Cataract Grade According to Surgeon-Rated Phacoemulsification Difficulty Variable Low difficulty (n=19) Intermediate difficulty (n=19) High difficulty (n=8) P value* CDE, median (IQR) 4.99 (3.13–6.64) 7.14 (6.56–11.17) 23.10 (15.58–47.05) <0.001 LOCS III-NO, median (IQR) 2 (2–3) 4 (3–4) 6 (5–6) <0.001 BCN10, median (IQR) 3 (3–4) 5 (4.5–6) 8 (7–8) <0.001 *Kruskal-Wallis test. Exploratory Multivariable Analysis of CDE Log transformation resulted in an approximately normal distribution of CDE (Shapiro-Wilk P=0.295). After adjustment for age and operating surgeon, LOCS III-NO remained strongly associated with log(CDE) ( β =0.413; HC3 95% CI, 0.295–0.532; P<0.001). This coefficient corresponds to an estimated 51.1% increase in CDE for each one-unit increase in LOCS III-NO, with an approximate 95% CI of 34.3% to 70.2%. The model had an adjusted R² of 0.623, AIC of 75.4, and BIC of 90.0. BCN10 also remained strongly associated with log(CDE) after adjustment for age and surgeon ( β =0.374; HC3 95% CI, 0.274–0.473; P<0.001). Each one-unit increase in BCN10 corresponded to an estimated 45.4% increase in CDE, with an approximate 95% CI of 31.6% to 60.5%. The BCN10-based model had an adjusted R² of 0.704, AIC of 64.3, and BIC of 78.9. Age was not significantly associated with CDE in either model. Table 5. Exploratory Multivariable Models for Log-Transformed CDE Model Nuclear grading coefficient β HC3 95% CI P value Adjusted R² AIC BIC LOCS III-NO + age + surgeon 0.413 0.295–0.532 <0.001 0.623 75.4 90.0 BCN10 + age + surgeon 0.374 0.274–0.473 <0.001 0.704 64.3 78.9 Although LOCS III-NO and BCN10 showed nearly identical unadjusted correlations with CDE, the BCN10-based model had a higher adjusted R² and lower information criteria than the LOCS III-NO model (adjusted R², 0.704 vs 0.623; AIC, 64.3 vs 75.4; BIC, 78.9 vs 90.0). These model-fit comparisons were exploratory and were not used as a formal test of superiority. Sensitivity Analyses To reduce potential confounding associated with nuclear disassembly technique, the analyses were repeated in the 43 eyes undergoing stop-and-chop. The principal findings remained unchanged. LOCS III-NO remained strongly associated with CDE ( ρ =0.729; P<0.001) and surgeon-rated phacoemulsification difficulty ( ρ =0.835; P<0.001). BCN10 remained strongly associated with CDE ( ρ =0.745; P<0.001) and surgeon-rated phacoemulsification difficulty ( ρ =0.882; P<0.001). CDE remained strongly correlated with subjective difficulty ( ρ =0.728; P<0.001). There remained no evidence of a meaningful difference between LOCS III-NO and BCN10 in their correlation with CDE ( ∆ρ = − 0.016; bootstrap 95% CI, − 0.114 to 0.082) or surgeon-rated phacoemulsification difficulty ( ∆ρ = − 0.047; 95% CI, − 0.142 to 0.032). In adjusted stop-and-chop-only models, LOCS III-NO remained significantly associated with log(CDE) ( β =0.408; P<0.001; adjusted R²=0.614; AIC=73.6), as did BCN10 ( β =0.362; P<0.001; adjusted R²=0.705; AIC=62.1). The consistency of these results suggests that the principal associations were not driven by the small number of cases performed with an alternative nuclear disassembly technique.

RkJQdWJsaXNoZXIy Mzc3MTg=