Libro Resumenes. VIII Jornadas de Investigación en Oftalmología 2026. Inteligencia artificial y transformación digital en investigación oftalmológica
VIII Jornadas de Investigación en Oftalmología · Universidad de Chile 64 Characteristic Value CDE, mean ± SD 12.28 ± 13.49 CDE, median (IQR) 7.14 (5.04–14.88) CDE range 1.80–69.50 Difficulty score, mean ± SD 4.41 ± 2.12 Difficulty score, median (IQR) 4.0 (3.0–5.75) Low difficulty, n (%) 19 (41.3) Intermediate difficulty, n (%) 19 (41.3) High difficulty, n (%) 8 (17.4) Stop-and-chop, n (%) 43 (93.5) Quick chop, n (%) 3 (6.5) Association of Cataract Grading With CDE LOCS III-NO demonstrated a strong positive association with CDE ( ρ =0.739; 95% bootstrap CI, 0.537–0.871; P<0.001). BCN10 showed a similarly strong positive association with CDE ( ρ =0.732; 95% CI, 0.532–0.860; P<0.001). The difference between the two dependent correlations was minimal ( ∆ρ =0.007), and the bootstrap 95% CI included zero ( − 0.097 to 0.123), providing no evidence that either grading system had a stronger unadjusted association with CDE. Association of Cataract Grading With Surgeon-Rated Phacoemulsification Difficulty Both grading systems demonstrated very strong associations with surgeon-rated phacoemulsification difficulty. LOCS III-NO correlated with surgeon-rated phacoemulsification difficulty at ρ =0.842 (95% CI, 0.712–0.922; P<0.001), whereas BCN10 correlated at ρ =0.862 (95% CI, 0.740–0.943; P<0.001). The correlation was numerically higher for BCN10, but the difference was small ( ∆ρ = − 0.020) and the corresponding bootstrap CI crossed zero (95% CI, − 0.119 to 0.075). Relationship Between CDE and Surgeon-Rated Phacoemulsification Difficulty CDE showed a strong positive correlation with surgeon-rated phacoemulsification difficulty ( ρ =0.741; 95% bootstrap CI, 0.538–0.875; P<0.001), indicating that procedures perceived as more technically demanding during the phacoemulsification step required greater ultrasound energy expenditure. This finding supports the consistency between objective energy use and the surgeon’s subjective assessment of phacoemulsification difficulty. LOCS III-NO and BCN10 were also highly correlated with each other ( ρ =0.905; 95% CI, 0.809–0.955; P<0.001), reflecting a strong association between both preoperative nuclear cataract grading systems. Adjusted Association Between CDE and Surgeon-Rated Phacoemulsification Difficulty In multivariable analysis adjusted for age and operating surgeon, surgeon-rated phacoemulsification difficulty remained strongly associated with log-transformed CDE ( β =0.304; HC3 95% CI, 0.237–0.371; P<0.001), corresponding to an estimated 35.5% increase in CDE for each one-point increase in perceived phacoemulsification difficulty. This association remained significant after additional adjustment for either LOCS III-NO (P<0.001) or BCN10 (P=0.018). Thus, surgeon-rated phacoemulsification difficulty remained associated with ultrasound energy expenditure after accounting for preoperative nuclear grade. Because the score was obtained after surgery, this analysis should be interpreted as supporting its role as a complementary contemporaneous measure of phacoemulsification complexity rather than as a preoperative predictor. Table 2. Correlations Between Cataract Grading and Measures of Phacoemulsification Difficulty Association Spearman ρ 95% bootstrap CI P value LOCS III-NO vs CDE 0.739 0.537–0.871 <0.001 BCN10 vs CDE 0.732 0.532–0.860 <0.001 LOCS III-NO vs difficulty score 0.842 0.712–0.922 <0.001 BCN10 vs difficulty score 0.862 0.740–0.943 <0.001 CDE vs difficulty score 0.741 0.538–0.875 <0.001 LOCS III-NO vs BCN10 0.905 0.809–0.955 <0.001 Table 3. Direct Comparison of LOCS III-NO and BCN10 Correlations Outcome ρ LOCS III-NO ρ BCN10 ∆ρ * 95% CI for ∆ρ CDE 0.739 0.732 0.007 − 0.097 to 0.123
Made with FlippingBook
RkJQdWJsaXNoZXIy Mzc3MTg=