Libro Resumenes. VIII Jornadas de Investigación en Oftalmología 2026. Inteligencia artificial y transformación digital en investigación oftalmológica
VIII Jornadas de Investigación en Oftalmología · Universidad de Chile 68 Finally, LOCS III-NO was the consistently available LOCS III nuclear variable in the analytical dataset. Future confirmatory studies may benefit from systematically recording both NO and NC and evaluating whether either nuclear component, or a predefined composite nuclear measure, provides additional predictive information. Future studies should not only compare predictive performance but also formally evaluate interobserver reproducibility, grading time, ease of use, and examiner preference, as these practical characteristics may influence the clinical adoption of either grading system. In particular, the visually intuitive photographic reference format of BCN10 may facilitate direct comparison with the patient’s nuclear appearance at the slit lamp; however, this potential practical advantage was not formally evaluated in the present study and should therefore be confirmed in dedicated comparative usability studies. Conclusions In this prospective multicenter, multisurgeon pilot study, LOCS III nuclear opalescence and BCN10 demonstrated strong and comparable associations with both cumulative dissipated energy and surgeon-rated phacoemulsification difficulty. No clear superiority of either grading system was demonstrated in the primary unadjusted correlation analyses. In exploratory analyses adjusted for age and surgeon, the BCN10-based model showed more favorable model-fit metrics, and the same pattern persisted after restriction to stop-and-chop procedures. Surgeon-rated phacoemulsification difficulty was strongly associated with CDE and discriminated clearly among low-, intermediate-, and high-difficulty procedures, supporting its potential value as a complementary measure of phacoemulsification complexity. These findings support the clinical utility of both nuclear cataract grading systems for preoperative assessment and provide preliminary effect estimates for a larger prospective study designed to determine whether BCN10 provides incremental predictive value beyond LOCS III-NO. Declarations Conflict of Interest The authors declare no conflicts of interest related to the cataract grading systems or phacoemulsification platform evaluated in this study. Ethics Written informed consent for participation in the study was obtained from all participants before study-related data collection. The study involved no additional therapeutic intervention, and surgical management was not modified by participation in the study. References 1. Chylack LT Jr, Wolfe JK, Singer DM, et al. The Lens Opacities Classification System III. Arch Ophthalmol. 1993;111(6):831-836. doi:10.1001/archopht.1993.01090060119035. 2. Karbassi M, Khu PM, Singer DM, Chylack LT Jr. Evaluation of Lens Opacities Classification System III applied at the slitlamp. Optom Vis Sci. 1993;70(11):923-928. doi:10.1097/00006324-199311000-00009. 3. Davison JA, Chylack LT. Clinical application of the Lens Opacities Classification System III in the performance of phacoemulsification. J Cataract Refract Surg. 2003;29(1):138-145. doi:10.1016/S0886-3350(02)01839-4. 4. Barraquer RI, Pinilla Cortés L, Allende MJ, et al. Validation of the Nuclear Cataract Grading System BCN 10. Ophthalmic Res. 2017;57(4):247-251. doi:10.1159/000456720. 5. Gupta M, Ram J, Jain A, Sukhija J, Chaudhary M. Correlation of nuclear density using the Lens Opacity Classification System III versus Scheimpflug imaging with phacoemulsification parameters. J Cataract Refract Surg. 2013;39(12):1818-1823. doi:10.1016/j.jcrs.2013.05.052. 6. Mahdy MAES, Eid MZ, Mohammed MA-B, Hafez A, Bhatia J. Relationship between endothelial cell loss and microcoaxial phacoemulsification parameters in noncomplicated cataract surgery. Clin Ophthalmol. 2012;6:503-510. doi:10.2147/OPTH.S29865. 7. Park JH, Lee SM, Kwon JW, et al. Ultrasound energy in phacoemulsification: a comparative analysis of phaco-chop and stop-and-chop techniques according to the degree of nuclear density. Ophthalmic Surg Lasers Imaging. 2010;41(2):236-241. doi:10.3928/15428877-20100303-13. 8. Pereira ACA, Porfírio F, Freitas LL, Belfort R Jr. Ultrasound energy and endothelial cell loss with stop-and-chop and nuclear preslice phacoemulsification. J Cataract Refract Surg. 2006;32(10):1661-1666. doi:10.1016/j.jcrs.2006.05.006.
Made with FlippingBook
RkJQdWJsaXNoZXIy Mzc3MTg=